Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38501564

RESUMO

INTRODUCTION: The relationships between baseline tissue local impedance (LI), contact force (CF), atrial fibrosis, and atrial rhythm are uninvestigated in a clinical setting. We compared the relationship of LI and CF between atrial fibrillation (AF) and sinus rhythm (SR) accounting for the effects of atrial fibrosis as assessed by bipolar voltage and LI. METHODS: Patients undergoing persistent AF ablation were recruited. LI was recorded referenced to patient blood pool (LIr) and concurrent to changes in CF, with data collected at the same locations in AF and SR. RESULTS: Twenty patients were recruited. 109 locations were sampled obtaining 1903 data points (SR: 966, AF: 937). CF correlated strongly with LI (repeated measures correlation = 0.64). The relationship between CF and LIr was logarithmic. Rhythm and CF had a significant main (both p < .0005) and interaction effect (p = .022) on tissue LI: AF demonstrated higher LIr values than SR for similar CF. Bipolar voltage had no effect on the relationship of CF to LIr in either rhythm. Assessing fibrosis using LIr showed an interaction effect with CF for LIr in SR and AF, (SR: p < .0005, AF: p = .01), with increased fibrosis showing lesser change in LIr per gram of CF. CONCLUSIONS: CF and rhythm significantly affect the measured LIr of LA myocardium. Optimal catheter-tissue coupling may be better achieved with higher levels of CF and in AF rather than SR. Atrial fibrosis, as assessed by LIr but not bipolar voltage, affected the CF-LI relationship.

2.
J Interv Card Electrophysiol ; 67(3): 649-656, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37875609

RESUMO

BACKGROUND: Ultra high-density mapping systems allow for comparison of atrial electroanatomical maps in unprecedented detail. Atrial scar determined by voltages and surface area between atria, rhythm and atrial fibrillation (AF) types was assessed. METHODS: Left (LA) and right atrial (RA) maps were created using Rhythmia HDx in patients listed for ablation for paroxysmal (PAF, sinus rhythm (SR) maps only) or persistent AF (PeAF, AF and SR maps). Electrograms on corresponding SR/AF maps were paired for direct comparison. Percentage surface area of scar was assigned low- (LVM, ≤ 0.05 mV), intermediate- (IVM, 0.05-0.5 mV) or normal voltage myocardium, (NVM, > 0.5 mV). RESULTS: Thirty-eight patients were recruited generating 96 maps using 913,480 electrograms. Paired SR-AF bipolar electrograms showed fair correlation in LA (Spearman's ρ = 0.32) and weak correlation in RA (ρ = 0.19) and were significantly higher in SR in both (LA: 0.61 mV (0.20-1.67) vs 0.31 mV (0.10-0.74), RA: 0.68 mV (0.19-1.88) vs 0.47 mV (0.14-1.07), p < 0.0005 both). Voltages were significantly higher in patients with PAF over PeAF, (LA: 1.13 mV (0.39-2.93) vs 0.52 mV (0.16-1.49); RA: 0.93 mV (0.24-2.46) vs 0.57 mV (0.17-1.69)). Minimal differences were seen in electrogram voltages between atria. Significantly more IVM/LVM surface areas were seen in AF over SR (LA only, p < 0005), and PeAF over PAF (LA: p = 0.01, RA: p = 0.04). There was minimal difference between atria within patients. CONCLUSIONS: Ultra high-density mapping shows paired electrograms correlate poorly between SR and AF. SR electrograms are typically (but not always) larger than those in AF. Patients with PeAF have a lower global electrogram voltage than those with PAF. Electrogram voltages are similar between atria within individual patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Cicatriz , Átrios do Coração/cirurgia , Apêndice Atrial/cirurgia , Miocárdio
3.
JACC Clin Electrophysiol ; 9(3): 330-340, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36371330

RESUMO

BACKGROUND: Predictors of effective ablation lesion delivery in the human left ventricle are not established, particularly in scar. Impedance drop and electrogram (EGM) attenuation are potential surrogates to assess this. OBJECTIVES: This study sought to establish the relationships between ablation index (AI) and force-time integral (FTI) with impedance drop and EGM attenuation in the human left ventricle. METHODS: Patients undergoing ventricular tachycardia ablation were recruited. EGMs were collected preablation and postablation, with impedance, AI, and FTI measured during. Based on preablation bipolar voltage, myocardium was adjudged a low-voltage myocardium (LVM) (<0.50 mV), intermediate-voltage myocardium (IVM) (0.51-1.50 mV), and normal-voltage myocardium (NVM) (>1.50 mV). Relationships between these parameters were explored. RESULTS: A total of 402 ablations were analyzed in 15 patients. The percent impedance drop correlated with AI and FTI (P < 0.0005; repeated-measures correlation coefficient: 0.54 and 0.44, respectively), a relationship that became weaker with increased myocardial fibrosis, (repeated-measures correlation coefficient for NVM, IVM, and LVM, AI: 0.67, 0.60, and 0.52, respectively; FTI: 0.59, 0.51, and 0.42, respectively). The curve between AI/FTI and impedance drop plateaued at 763 AI and 713 gram-seconds, an impedance drop of 7.5%. Shallower curves occurred progressively from NVM to LVM (P < 0.0005). Mixed models demonstrated that AI and FTI had a greater effect on impedance drop than myocardial fibrosis, drift, or orientation, (standardized ß: 0.54 and 0.48, respectively). EGMs were attenuated with ablation (29.3%; IQR: 4.4%-53.3%; P < 0.0005), but attenuation did not correlate with AI or FTI. CONCLUSIONS: On biophysical analysis, ablation beyond an AI of 763 and FTI of 713 gs offers minimal additional efficacy on average. Fibrosis blunts ablation efficacy. AI is a stronger correlate with impedance drop than FTI. EGM attenuation does not correlate with ablation parameters. (Late Potentials and Ablation Index in Ventricular Tachycardia Ablation; NCT03437408).


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Ventrículos do Coração/cirurgia , Miocárdio , Taquicardia Ventricular/cirurgia , Fibrose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...